A three-blade GFRP drum platform with a deep shroud and locking casters for focused industrial airflow.
Compare This Family ↗
Point-Of-Use Airflow
AirMoveX AXM-D Series
GFRP Drum Fan
A three-blade GFRP drum platform with a deep shroud and locking casters for focused industrial airflow.
- Three wide GFRP blades
- PMSM drive
- Corrosion-resistant rotor
- Locking casters
- Size Range
- 37-53 in
- Drive
- PMSM brushless motor
- Max Air Volume
- 660 m³/min
- Installation
- Factory assembled / wheeled
Product Overview
Configured Around The Building, Not Just The Diameter
A three-blade GFRP drum platform with a deep shroud and locking casters for focused industrial airflow.
- Drive
- PMSM brushless motor
- Blade
- GFRP / 3 pcs
- Control
- VFD with protection module
- Install
- Factory assembled / wheeled
Production lines, workshops, livestock facilities, events, gyms and food-processing areas
Reference values support preliminary selection. Final voltage, size, control, installation accessories, certification scope and packing are confirmed in the quotation.
Why This Model May Fit
AirMoveX AXM-D Series In The AirMoveX System
Use this card as a preliminary fit check. It explains the role of the series from the catalog; the final model, voltage, accessories and installation scope still belong in the quotation.
Typical applications: Production lines, workshops, livestock facilities, events, gyms and food-processing areas.
VFD with protection module. Available variants begin at 1.35 m / 53 in; review the table below for the series range.
Confirm voltage, selected size, accessories, certification scope, packing, delivery terms and the site installation method against the final configuration.
Carry This Model Into A Quote ↗Available Configurations
AirMoveX AXM-D Series Model Specifications
Select a preliminary configuration below. The inquiry button carries the exact series and model into the project form.
| AirMoveX Model | Diameter | Voltage | Power | Current | Max Speed | Max Air Volume | Coverage / Capacity | Sound | Blades | Net Weight | Inquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AXM-D53 | 1.35 m / 53 in | 220 V / 50-60 Hz | 600 W | 3 A | 500 rpm | 660 m³/min | — | ≤ 65 dB(A) | 3 | 48 kg | Quote This Model ↗ |
| AXM-D43 | 1.10 m / 43 in | 220 V / 50-60 Hz | 560 W | 2.8 A | 600 rpm | 410 m³/min | — | ≤ 65 dB(A) | 3 | 46 kg | Quote This Model ↗ |
| AXM-D37 | 0.95 m / 37 in | 220 V / 50-60 Hz | 530 W | 2.6 A | 680 rpm | 300 m³/min | — | ≤ 65 dB(A) | 3 | 44 kg | Quote This Model ↗ |
Configuration 01
AXM-D53
1.35 m / 53 in- Diameter
- 1.35 m / 53 in
- Voltage
- 220 V / 50-60 Hz
- Current
- 3 A
- Max Speed
- 500 rpm
- Sound
- ≤ 65 dB(A)
- Blades
- 3
- Net Weight
- 48 kg
Configuration 02
AXM-D43
1.10 m / 43 in- Diameter
- 1.10 m / 43 in
- Voltage
- 220 V / 50-60 Hz
- Current
- 2.8 A
- Max Speed
- 600 rpm
- Sound
- ≤ 65 dB(A)
- Blades
- 3
- Net Weight
- 46 kg
Configuration 03
AXM-D37
0.95 m / 37 in- Diameter
- 0.95 m / 37 in
- Voltage
- 220 V / 50-60 Hz
- Current
- 2.6 A
- Max Speed
- 680 rpm
- Sound
- ≤ 65 dB(A)
- Blades
- 3
- Net Weight
- 44 kg
Selection Guides
Resolve These Questions Before Choosing AirMoveX AXM-D Series
Use the guides for the selection method, then confirm the exact configuration against the project documents.
Will the casters and brakes suit this floor?
Check the complete AXM-D operating mass, floor and parking position against the offered caster and brake specifications.
What does an FRP blade change in the buying decision?
Keep the AXM-D blade material separate from complete-fan corrosion suitability, spark resistance and documented performance.
Considering a battery fan instead?
The listed AXM-D variants require a 220 V supply. Use this separate battery-fan checklist to compare a cordless alternative; it does not establish an AXM-D battery option.
Portable Fan Stability: A Brake Does Not Prevent Every Tip
A caster brake can resist rolling without preventing a fan from tipping. Check the complete frame, adjustment and placement conditions rather than one wheel feature.
Workstation Airspeed Survey: Measure Where People Actually Work
A strong reading at the fan outlet says little about a person behind a packing bench. Measure the occupied work position and retain the conditions of the survey.
Fan Guard Cleaning Access: Check the Service Job Before Buying
A removable guard may still be awkward to clean in the installed position. Check access, isolation and reassembly before accepting a maintenance promise.
Battery or Corded Industrial Fan: Plan the Whole Shift
Choose battery or mains power by the working day: available sockets, relocation, charging windows and what happens when the battery runs out.
Drum or Open-Frame Fan: Compare the Air Path, Not the Shell
A drum housing and an open frame change handling and the air path. Compare complete dimensions and comparable performance evidence, not appearance.
Industrial Fan Warranty: Who Pays for the Service Visit?
A warranty period is not a service plan. Set out parts, labour, access equipment, travel and freight responsibilities before ordering an industrial fan.
Fans Near Lightweight Packaging: Test the Loose Material, Too
Before placing a fan beside light cartons, film or labels, test product stability and useful air movement together. More speed is not automatically a better result.
Fan Inches to Millimetres: Rotor Size Is Not Frame Size
Convert nominal fan inches to millimetres, then request the actual rotor, guard and frame dimensions. An inch label is not a door-clearance drawing.
FRP Fan Housing and Blades: Put Each Material on Its Own Line
An FRP fan casing does not prove FRP blades. Specify material separately for the casing, rotor, guard, fasteners and support before comparing proposals.
Private-Label Industrial Fans: Approve the Identity Before the Carton
Before requesting a private-label fan, agree the exact model, legal identities, nameplate data, manual and packaging changes. A logo change is not a complete OEM specification.
Industrial Fan Sample Orders: Agree the Pass Criteria Before Paying
Agree a sample fan acceptance plan before payment: configuration, included parts, inspection conditions, discrepancy handling and what approval does not cover.
Single-Phase or Three-Phase Fan: Read the Drive Input First
Compare the site supply, controller input and motor output separately before ordering a single-phase or three-phase industrial fan.
Several Fans on One Circuit: Running Amps Do Not Describe the Start
For several industrial fans, collect running and starting-current evidence for the complete offered package before agreeing simultaneous or staged starting.
Fan Extension Leads: Check Voltage Drop and the Entire Cable Route
A longer fan cable can introduce voltage drop, but cable size, protection and extension-lead suitability require the actual electrical installation details.
Fans for Wet Floors: Move Air Without Pretending to Remove the Water
A fan may assist evaporation from a wet floor, but placement must keep electrical equipment and routes suitable for the conditions and the wet area controlled.
Fan Incoterms and Landed Cost: Name the Place, Then Compare
Compare industrial-fan quotations using the Incoterms rule, named place and itemized buyer costs. An equipment price is not a landed-cost quotation.
Fan FAT and SAT: Agree Which Question Each Test Must Answer
Separate factory acceptance from site acceptance: agree the configuration, test conditions, pass criteria and records for each stage before ordering.
Real installations · same factory
Mobile And Drum Fans running on site
Project Documents
Request The Documents That Match The Final Configuration
Document scope is tied to the quoted model and destination market. This avoids presenting a generic certificate or drawing as if it covered every configuration.
Technical Datasheet
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Installation And Dimension Drawing
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Certificate And Packing Scope
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗First decide whether the task is circulation, spot air movement, clean-air supply or contaminant exhaust. A portable fan cannot perform every role safely.
Open The Field GuideDo not choose from a search phrase such as 24, 36, 42 or 48 inch. Start with the real catalog sizes, then check airflow task, access, power, noise and mobility.
Open The Field GuideProject Inquiry
Confirm AirMoveX AXM-D Series For Your Site
Share dimensions, clear height, available power, quantity and destination. The exact series will already be attached to the inquiry.