A beltless, six-blade exhaust platform with FRP blades and housing for wall-mounted building air exchange.
Compare This Family ↗
Targeted Ventilation
AirMoveX AXE-E Series
FRP Exhaust Fan
A beltless, six-blade exhaust platform with FRP blades and housing for wall-mounted building air exchange.
AI-generated product illustration, not a product or installation photograph. Confirm the final configuration against the selected-model documents.
- Six FRP blades
- PMSM beltless drive
- FRP housing
- Wall-ready square frame
- Size Range
- 26-42 in
- Drive
- PMSM brushless motor
- Max Air Volume
- 546 m³/min
- Installation
- Wall opening
Product Overview
Configured Around The Building, Not Just The Diameter
A beltless, six-blade exhaust platform with FRP blades and housing for wall-mounted building air exchange.
- Drive
- PMSM brushless motor
- Blade
- FRP / 6 pcs
- Control
- VFD with protection module
- Install
- Wall opening
Workshops, farms and livestock buildings, subject to airflow, environmental and installation checks
Reference values support preliminary selection. Final voltage, size, control, installation accessories, certification scope and packing are confirmed in the quotation.
Why This Model May Fit
AirMoveX AXE-E Series In The AirMoveX System
Use this card as a preliminary fit check. It explains the role of the series from the catalog; the final model, voltage, accessories and installation scope still belong in the quotation.
Typical applications: Workshops, farms and livestock buildings, subject to airflow, environmental and installation checks.
VFD with protection module. Available variants begin at 1.06 m / 42 in; review the table below for the series range.
Confirm voltage, selected size, accessories, certification scope, packing, delivery terms and the site installation method against the final configuration.
Carry This Model Into A Quote ↗Available Configurations
AirMoveX AXE-E Series Model Specifications
Select a preliminary configuration below. The inquiry button carries the exact series and model into the project form.
| AirMoveX Model | Diameter | Voltage | Power | Current | Max Speed | Max Air Volume | Coverage / Capacity | Sound | Blades | Net Weight | Inquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AXE-E42 | 1.06 m / 42 in | 220 V / 50-60 Hz | 400 W | — | 550 rpm | 546 m³/min | — | ≤ 65 dB(A) | 6 | 28 kg | Quote This Model ↗ |
| AXE-E36 | 0.90 m / 36 in | 220 V / 50-60 Hz | 400 W | — | 720 rpm | 471 m³/min | — | ≤ 63 dB(A) | 6 | 26 kg | Quote This Model ↗ |
| AXE-E26 | 0.65 m / 26 in | 220 V / 50-60 Hz | 350 W | — | 750 rpm | 389 m³/min | — | ≤ 63 dB(A) | 6 | 23 kg | Quote This Model ↗ |
Configuration 01
AXE-E42
1.06 m / 42 in- Diameter
- 1.06 m / 42 in
- Voltage
- 220 V / 50-60 Hz
- Current
- —
- Max Speed
- 550 rpm
- Sound
- ≤ 65 dB(A)
- Blades
- 6
- Net Weight
- 28 kg
Configuration 02
AXE-E36
0.90 m / 36 in- Diameter
- 0.90 m / 36 in
- Voltage
- 220 V / 50-60 Hz
- Current
- —
- Max Speed
- 720 rpm
- Sound
- ≤ 63 dB(A)
- Blades
- 6
- Net Weight
- 26 kg
Configuration 03
AXE-E26
0.65 m / 26 in- Diameter
- 0.65 m / 26 in
- Voltage
- 220 V / 50-60 Hz
- Current
- —
- Max Speed
- 750 rpm
- Sound
- ≤ 63 dB(A)
- Blades
- 6
- Net Weight
- 23 kg
Before Selecting AirMoveX AXE-E Series
FRP is a material, not a chemical approval. Confirm the actual chemicals, concentration, temperature, exposure and cleaning method against the selected materials. FRP housing alone does not establish suitability for every corrosive atmosphere, hazardous area or high-temperature process.
Select at the system pressure. Catalog maximum air volume is not the installed duty point. Obtain selected-model performance at the required static pressure and account for guards, shutters, openings and the make-up air path.
Confirm the complete wall installation. Confirm supply voltage and frequency, the motor/controller pairing, airflow direction, wall opening, mounting details and service access before the quotation is finalized.
Selection Guides
Resolve These Questions Before Choosing AirMoveX AXE-E Series
Use the guides for the selection method, then confirm the exact configuration against the project documents.
Choose materials for the actual corrosive exposure
Check the complete assembly, not just the FRP housing, against the site chemicals and operating conditions.
Read airflow at the required static pressure
Use a fan curve and a system duty point instead of treating maximum catalog air volume as guaranteed installed airflow.
Check protection beyond the fan motor
Confirm which component the IP rating covers and how the controller, connectors and cable entries will be protected.
Fan Start Command, Run Feedback and Airflow Proof Are Different
A dashboard saying “run” can mean a command was sent, a drive is active or airflow was actually proved. Those are three different answers.
0–10 V or 4–20 mA Fan Control: Match the Signal Before Wiring
“Analog control” is not enough information for a controls contractor. Voltage, current, reference and scaling must agree at both ends.
Fan Selection at Altitude: Keep Actual Airflow and Density Together
A sea-level fan curve and a mountain-site airflow requirement can look compatible until the density basis is checked. Keep the quantities together.
Fan Efficiency: Ask Where the Power Measurement Starts
Two efficiency percentages can disagree because they measure different boundaries. Ask where the power measurement starts before comparing them.
Static or Total Fan Pressure: Compare Like With Like
A pressure number without its definition can make a weaker selection look stronger. Keep static and total pressure on separate lines until the basis is clear.
HVLS vs exhaust: circulation or air exchange?
Separate the circulation layout from exhaust duty and replacement air before comparing quotations.
Industrial Fan Export Packaging: Specify What the Crate Must Protect
For an industrial fan shipment, specify component restraint, separation, moisture protection and the receiving evidence before choosing a crate.
FRP Fan Housing and Blades: Put Each Material on Its Own Line
An FRP fan casing does not prove FRP blades. Specify material separately for the casing, rotor, guard, fasteners and support before comparing proposals.
Fan Declaration, Certificate or Test Report: Match the Model First
A declaration, certificate and test report answer different questions. Check issuer, product identity, scope and configuration before using any document as purchase evidence.
Fan Submittal Drawings: Ask for the Installed Envelope
A useful industrial-fan submittal drawing identifies the offered revision, interfaces, service space and open items. A brochure outline is not an installation drawing.
Stopped Exhaust Fans Can Windmill: A Stop Command Is Not Restraint
An exhaust fan can be driven by external airflow after its motor stops. Treat windmilling as an installation and service question, not a fault diagnosis from a photograph.
Fan Pressure Units: Convert Pa, in. w.g. and mm w.g. on One Basis
Convert fan pressure units consistently: 1 conventional in.w.g. is about 249.089 Pa and 1 conventional mm.w.g. is 9.80665 Pa. Keep the pressure definition unchanged.
Fans in Series or Parallel: Combine the Curves, Not the Catalog Numbers
For ideal identical fans, series curves add pressure at equal flow and parallel curves add flow at equal pressure. The installed operating point still comes from the system curve.
Project Documents
Request The Documents That Match The Final Configuration
Document scope is tied to the quoted model and destination market. This avoids presenting a generic certificate or drawing as if it covered every configuration.
Technical Datasheet
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Installation And Dimension Drawing
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Certificate And Packing Scope
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Use the industrial exhaust fan sizing calculator to document building volume and the project ACH input. Then confirm AirMoveX AXE-E Series performance at the required static pressure before selecting a configuration.
Open The CFM And ACH GuideA useful maintenance plan starts with isolation and condition evidence. It does not invent one service interval for every fan, contaminant and duty cycle.
Open The Field GuideFRP is not one universal corrosion-proof material. The chemical, concentration, temperature, resin system, hardware and cleaning exposure must be reviewed together.
Open The Field GuideProject Inquiry
Confirm AirMoveX AXE-E Series For Your Site
Share dimensions, clear height, available power, quantity and destination. The exact series will already be attached to the inquiry.