Home/Product Models/HVLS Fans/AirMoveX AXV-C Series
AirMoveX compact architectural fan shown in a purpose-matched installation scene
Ceiling Fan Systems7.8-11.8 ft

Ceiling Air Movement

AirMoveX AXV-C Series

Compact Architectural Fan

A slim matte-black five-blade platform for lower ceilings and interiors where appearance matters as much as circulation.

  • Slim five-blade form
  • Remote 10-speed control
  • Integrated-light option
  • PMSM brushless drive
Size Range
7.8-11.8 ft
Drive
PMSM brushless motor
Max Air Volume
5,700 m³/min
Installation
Interior ceiling platform

Product Overview

Configured Around The Building, Not Just The Diameter

A slim matte-black five-blade platform for lower ceilings and interiors where appearance matters as much as circulation.

Drive
PMSM brushless motor
Blade
Powder-coated steel / 5 pcs
Control
Remote / 10 speed
Install
Interior ceiling platform
Typical Applications

Commercial interiors, dining halls, showrooms, schools, homes and light industrial spaces

Reference values support preliminary selection. Final voltage, size, control, installation accessories, certification scope and packing are confirmed in the quotation.

Why This Model May Fit

AirMoveX AXV-C Series In The AirMoveX System

Use this card as a preliminary fit check. It explains the role of the series from the catalog; the final model, voltage, accessories and installation scope still belong in the quotation.

Product familyCeiling Fan Systems

A slim matte-black five-blade platform for lower ceilings and interiors where appearance matters as much as circulation.

Compare This Family ↗
Installation roleInterior ceiling platform

Typical applications: Commercial interiors, dining halls, showrooms, schools, homes and light industrial spaces.

Drive and controlPMSM brushless motor

Remote / 10 speed. Available variants begin at 3.60 m / 11.8 ft; review the table below for the series range.

Confirm before orderingProject-specific quotation

Confirm voltage, selected size, accessories, certification scope, packing, delivery terms and the site installation method against the final configuration.

Carry This Model Into A Quote ↗

Available Configurations

AirMoveX AXV-C Series Model Specifications

Select a preliminary configuration below. The inquiry button carries the exact series and model into the project form.

AirMoveX ModelDiameterVoltagePowerCurrentMax SpeedMax Air VolumeCoverage / CapacitySoundBladesNet WeightInquiry
AXV-C12-53.60 m / 11.8 ft220 V / 50-60 Hz400 W2.8 A95 rpm5,700 m³/min460 m²≤ 40 dB(A)523 kg Quote This Model ↗
AXV-C11-53.30 m / 10.8 ft220 V / 50-60 Hz400 W2.5 A105 rpm5,350 m³/min350 m²≤ 40 dB(A)522 kg Quote This Model ↗
AXV-C10-53.00 m / 9.8 ft220 V / 50-60 Hz350 W2.2 A115 rpm5,200 m³/min290 m²≤ 40 dB(A)521 kg Quote This Model ↗
AXV-C09-52.70 m / 8.8 ft220 V / 50-60 Hz350 W2 A125 rpm4,600 m³/min240 m²≤ 40 dB(A)520 kg Quote This Model ↗
AXV-C08-52.40 m / 7.8 ft220 V / 50-60 Hz350 W1.8 A135 rpm4,100 m³/min190 m²≤ 40 dB(A)519 kg Quote This Model ↗

Configuration 01

AXV-C12-5

3.60 m / 11.8 ft
Max Air Volume5,700 m³/min
Power400 W
Coverage460 m²
Diameter
3.60 m / 11.8 ft
Voltage
220 V / 50-60 Hz
Current
2.8 A
Max Speed
95 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
23 kg
Request This Configuration

Configuration 02

AXV-C11-5

3.30 m / 10.8 ft
Max Air Volume5,350 m³/min
Power400 W
Coverage350 m²
Diameter
3.30 m / 10.8 ft
Voltage
220 V / 50-60 Hz
Current
2.5 A
Max Speed
105 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
22 kg
Request This Configuration

Configuration 03

AXV-C10-5

3.00 m / 9.8 ft
Max Air Volume5,200 m³/min
Power350 W
Coverage290 m²
Diameter
3.00 m / 9.8 ft
Voltage
220 V / 50-60 Hz
Current
2.2 A
Max Speed
115 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
21 kg
Request This Configuration

Configuration 04

AXV-C09-5

2.70 m / 8.8 ft
Max Air Volume4,600 m³/min
Power350 W
Coverage240 m²
Diameter
2.70 m / 8.8 ft
Voltage
220 V / 50-60 Hz
Current
2 A
Max Speed
125 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
20 kg
Request This Configuration

Configuration 05

AXV-C08-5

2.40 m / 7.8 ft
Max Air Volume4,100 m³/min
Power350 W
Coverage190 m²
Diameter
2.40 m / 7.8 ft
Voltage
220 V / 50-60 Hz
Current
1.8 A
Max Speed
135 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
19 kg
Request This Configuration
Power Is Not Annual Energy

The values above are supplied catalog references. Use exact-model input at the intended speed and the site's real operating hours to estimate kWh and cost.

Open The Power-Consumption Method

Selection Guides

Resolve These Questions Before Choosing AirMoveX AXV-C Series

Use the guides for the selection method, then confirm the exact configuration against the project documents.

Real installations · same factory

Ceiling Fan Systems running on site

See all project photos
Metal fabrication workshop — 6-blade HVLS fan
Metal fabrication workshop6-blade HVLS fan
Steel-truss production hall — 6-blade HVLS fan
Steel-truss production hall6-blade HVLS fan
Live concert hall — HVLS fan above the crowd
Live concert hallHVLS fan above the crowd

Project Documents

Request The Documents That Match The Final Configuration

Document scope is tied to the quoted model and destination market. This avoids presenting a generic certificate or drawing as if it covered every configuration.

01

Technical Datasheet

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
02

Installation And Dimension Drawing

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
03

Certificate And Packing Scope

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
Planning The Service Record?

Use the HVLS preventive maintenance checklist to organize isolation, mounting and retention, drive, hub, airfoils, controls and return-to-service evidence. Exact intervals and limits still come from the current AirMoveX AXV-C Series documentation.

Open The Maintenance Checklist
HVLS Destratification

Winter destratification is a controlled mixing job: move warmer ceiling air back into the occupied zone slowly enough that people do not feel an unwanted draft.

Open The Field Guide
HVLS Specification Checklist

A good specification defines the building, useful-air result, evidence, installation and commissioning. It does not simply ask suppliers for their biggest airflow number.

Open The Field Guide
HVLS Installation Cost

Equipment price is only one line. Structure, mounting, lift access, electrical work, controls, fire coordination, shutdown, commissioning, freight and site constraints shape installed cost.

Open The Field Guide

Project Inquiry

Confirm AirMoveX AXV-C Series For Your Site

Share dimensions, clear height, available power, quantity and destination. The exact series will already be attached to the inquiry.

Start This Product Inquiry