A five-blade ceiling fan with integrated illumination for occupied commercial, education and residential spaces.
Compare This Family ↗
Ceiling Air Movement
AirMoveX AXV-R Series
Commercial Ceiling Fan With Light
A five-blade ceiling fan with integrated illumination for occupied commercial, education and residential spaces.
- Integrated LED light
- Five ABS blades
- Remote 10-speed control
- Summer/winter circulation
- Size Range
- 79-98 in
- Drive
- PMSM brushless motor
- Max Air Volume
- 2,650 m³/min
- Installation
- Occupied interior spaces
Product Overview
Configured Around The Building, Not Just The Diameter
A five-blade ceiling fan with integrated illumination for occupied commercial, education and residential spaces.
- Drive
- PMSM brushless motor
- Blade
- ABS / 5 pcs
- Control
- Remote / 10 speed
- Install
- Occupied interior spaces
Retail, classrooms, dining rooms, lobbies, activity rooms and residential interiors
Reference values support preliminary selection. Final voltage, size, control, installation accessories, certification scope and packing are confirmed in the quotation.
Why This Model May Fit
AirMoveX AXV-R Series In The AirMoveX System
Use this card as a preliminary fit check. It explains the role of the series from the catalog; the final model, voltage, accessories and installation scope still belong in the quotation.
Typical applications: Retail, classrooms, dining rooms, lobbies, activity rooms and residential interiors.
Remote / 10 speed. Available variants begin at 2.50 m / 98 in; review the table below for the series range.
Confirm voltage, selected size, accessories, certification scope, packing, delivery terms and the site installation method against the final configuration.
Carry This Model Into A Quote ↗Available Configurations
AirMoveX AXV-R Series Model Specifications
Select a preliminary configuration below. The inquiry button carries the exact series and model into the project form.
| AirMoveX Model | Diameter | Voltage | Power | Current | Max Speed | Max Air Volume | Coverage / Capacity | Sound | Blades | Net Weight | Inquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AXV-R98-5 | 2.50 m / 98 in | 220 V / 50-60 Hz | 400 W | 3.2 A | 150 rpm | 2,650 m³/min | 310 m² | ≤ 40 dB(A) | 5 | 18 kg | Quote This Model ↗ |
| AXV-R79-5 | 2.00 m / 79 in | 220 V / 50-60 Hz | 360 W | 3 A | 200 rpm | 2,100 m³/min | 210 m² | ≤ 40 dB(A) | 5 | 17 kg | Quote This Model ↗ |
Configuration 01
AXV-R98-5
2.50 m / 98 in- Diameter
- 2.50 m / 98 in
- Voltage
- 220 V / 50-60 Hz
- Current
- 3.2 A
- Max Speed
- 150 rpm
- Sound
- ≤ 40 dB(A)
- Blades
- 5
- Net Weight
- 18 kg
Configuration 02
AXV-R79-5
2.00 m / 79 in- Diameter
- 2.00 m / 79 in
- Voltage
- 220 V / 50-60 Hz
- Current
- 3 A
- Max Speed
- 200 rpm
- Sound
- ≤ 40 dB(A)
- Blades
- 5
- Net Weight
- 17 kg
The values above are supplied catalog references. Use exact-model input at the intended speed and the site's real operating hours to estimate kWh and cost.
Open The Power-Consumption MethodSelection Guides
Resolve These Questions Before Choosing AirMoveX AXV-R Series
Use the guides for the selection method, then confirm the exact configuration against the project documents.
Can the fan and light be controlled independently?
Have the offered AXV-R controls, lighting supply and power-return behavior confirmed in writing; an integrated light does not answer those questions.
Replacement Fan Remote: Match the Receiver, Not the Button Count
A replacement ceiling-fan remote must match the receiver and control generation. Similar buttons or radio frequency alone do not prove compatibility.
Real installations · same factory
Ceiling Fan Systems running on site
Project Documents
Request The Documents That Match The Final Configuration
Document scope is tied to the quoted model and destination market. This avoids presenting a generic certificate or drawing as if it covered every configuration.
Technical Datasheet
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Installation And Dimension Drawing
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Certificate And Packing Scope
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Use the HVLS preventive maintenance checklist to organize isolation, mounting and retention, drive, hub, airfoils, controls and return-to-service evidence. Exact intervals and limits still come from the current AirMoveX AXV-R Series documentation.
Open The Maintenance ChecklistWinter destratification is a controlled mixing job: move warmer ceiling air back into the occupied zone slowly enough that people do not feel an unwanted draft.
Open The Field GuideA good specification defines the building, useful-air result, evidence, installation and commissioning. It does not simply ask suppliers for their biggest airflow number.
Open The Field GuideEquipment price is only one line. Structure, mounting, lift access, electrical work, controls, fire coordination, shutdown, commissioning, freight and site constraints shape installed cost.
Open The Field GuideProject Inquiry
Confirm AirMoveX AXV-R Series For Your Site
Share dimensions, clear height, available power, quantity and destination. The exact series will already be attached to the inquiry.