Home/Product Models/HVLS Fans/AirMoveX AXV-H Series
AI illustration of a six-blade AXV-H ceiling fan in a high-bay industrial building
Ceiling Fan Systems18-24 ft

Ceiling Air Movement

AirMoveX AXV-H Series

Premium Six-Blade HVLS Fan

The flagship direct-drive platform for broad, low-speed air movement across high-bay industrial buildings.

AI-generated product illustration, not a product or installation photograph. Confirm the final configuration against the selected-model documents.

  • PMSM direct drive
  • Six AL6063 airfoil blades
  • Motor IP55 (catalog rating)
  • VFD safety protection
Size Range
18-24 ft
Drive
PMSM direct drive
Max Air Volume
14,900 m³/min
Installation
Recommended clear height ≥ 7 m

Product Overview

Configured Around The Building, Not Just The Diameter

The flagship direct-drive platform for broad, low-speed air movement across high-bay industrial buildings.

Drive
PMSM direct drive
Blade
AL6063 / 6 pcs
Control
Variable frequency drive
Install
Recommended clear height ≥ 7 m
Typical Applications

High-bay warehouses, factories, logistics centers, farms, sports venues and large public halls

Reference values support preliminary selection. Final voltage, size, control, installation accessories, certification scope and packing are confirmed in the quotation.

Why This Model May Fit

AirMoveX AXV-H Series In The AirMoveX System

Use this card as a preliminary fit check. It explains the role of the series from the catalog; the final model, voltage, accessories and installation scope still belong in the quotation.

Product familyCeiling Fan Systems

The flagship direct-drive platform for broad, low-speed air movement across high-bay industrial buildings.

Compare This Family ↗
Installation roleRecommended clear height ≥ 7 m

Typical applications: High-bay warehouses, factories, logistics centers, farms, sports venues and large public halls.

Drive and controlPMSM direct drive

Variable frequency drive. Available variants begin at 7.32 m / 24 ft; review the table below for the series range.

Confirm before orderingProject-specific quotation

Confirm voltage, selected size, accessories, certification scope, packing, delivery terms and the site installation method against the final configuration.

Carry This Model Into A Quote ↗

Available Configurations

AirMoveX AXV-H Series Model Specifications

Select a preliminary configuration below. The inquiry button carries the exact series and model into the project form.

AirMoveX ModelDiameterVoltagePowerCurrentMax SpeedMax Air VolumeCoverage / CapacitySoundBladesNet WeightInquiry
AXV-H24-67.32 m / 24 ft220/380 V / 50-60 Hz1,500 W3.8 A50 rpm14,900 m³/min1,200 m²≤ 40 dB(A)6121 kg Quote This Model ↗
AXV-H22-66.72 m / 22 ft220/380 V / 50-60 Hz1,400 W3.6 A55 rpm13,500 m³/min1,100 m²≤ 40 dB(A)6117 kg Quote This Model ↗
AXV-H20-66.12 m / 20 ft220/380 V / 50-60 Hz1,200 W3.1 A60 rpm12,200 m³/min1,000 m²≤ 40 dB(A)6105 kg Quote This Model ↗
AXV-H18-65.52 m / 18 ft220/380 V / 50-60 Hz900 W2.5 A65 rpm10,800 m³/min900 m²≤ 40 dB(A)6100 kg Quote This Model ↗

Configuration 01

AXV-H24-6

7.32 m / 24 ft
Max Air Volume14,900 m³/min
Power1,500 W
Coverage1,200 m²
Diameter
7.32 m / 24 ft
Voltage
220/380 V / 50-60 Hz
Current
3.8 A
Max Speed
50 rpm
Sound
≤ 40 dB(A)
Blades
6
Net Weight
121 kg
Request This Configuration

Configuration 02

AXV-H22-6

6.72 m / 22 ft
Max Air Volume13,500 m³/min
Power1,400 W
Coverage1,100 m²
Diameter
6.72 m / 22 ft
Voltage
220/380 V / 50-60 Hz
Current
3.6 A
Max Speed
55 rpm
Sound
≤ 40 dB(A)
Blades
6
Net Weight
117 kg
Request This Configuration

Configuration 03

AXV-H20-6

6.12 m / 20 ft
Max Air Volume12,200 m³/min
Power1,200 W
Coverage1,000 m²
Diameter
6.12 m / 20 ft
Voltage
220/380 V / 50-60 Hz
Current
3.1 A
Max Speed
60 rpm
Sound
≤ 40 dB(A)
Blades
6
Net Weight
105 kg
Request This Configuration

Configuration 04

AXV-H18-6

5.52 m / 18 ft
Max Air Volume10,800 m³/min
Power900 W
Coverage900 m²
Diameter
5.52 m / 18 ft
Voltage
220/380 V / 50-60 Hz
Current
2.5 A
Max Speed
65 rpm
Sound
≤ 40 dB(A)
Blades
6
Net Weight
100 kg
Request This Configuration

Before Selecting AirMoveX AXV-H Series

Air circulation, not fresh-air supply. AXV-H moves air within the building. It does not provide an outdoor-air exchange rate or replace source capture for fumes, dust or other process contaminants.

Read the rating at component level. Airflow, coverage and sound figures are supplied catalog references, not measured results for this building. The catalog motor IP55 rating does not establish the same rating for the controller, connectors or complete installation.

Check the mounting and electrical package. Review clear height, the supporting structure, obstacles, mounting details and the exact motor/controller supply before ordering. Confirm site clearances and installation requirements against the selected-model documents.

Power Is Not Annual Energy

The values above are supplied catalog references. Use exact-model input at the intended speed and the site's real operating hours to estimate kWh and cost.

Open The Power-Consumption Method

Selection Guides

Resolve These Questions Before Choosing AirMoveX AXV-H Series

Use the guides for the selection method, then confirm the exact configuration against the project documents.

Real installations · same factory

Ceiling Fan Systems running on site

See all project photos
Metal fabrication workshop — 6-blade HVLS fan
Metal fabrication workshop6-blade HVLS fan
Steel-truss production hall — 6-blade HVLS fan
Steel-truss production hall6-blade HVLS fan
Live concert hall — HVLS fan above the crowd
Live concert hallHVLS fan above the crowd

Project Documents

Request The Documents That Match The Final Configuration

Document scope is tied to the quoted model and destination market. This avoids presenting a generic certificate or drawing as if it covered every configuration.

01

Technical Datasheet

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
02

Installation And Dimension Drawing

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
03

Certificate And Packing Scope

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
Planning The Service Record?

Use the HVLS preventive maintenance checklist to organize isolation, mounting and retention, drive, hub, airfoils, controls and return-to-service evidence. Exact intervals and limits still come from the current AirMoveX AXV-H Series documentation.

Open The Maintenance Checklist
HVLS Destratification

Winter destratification is a controlled mixing job: move warmer ceiling air back into the occupied zone slowly enough that people do not feel an unwanted draft.

Open The Field Guide
HVLS Specification Checklist

A good specification defines the building, useful-air result, evidence, installation and commissioning. It does not simply ask suppliers for their biggest airflow number.

Open The Field Guide
HVLS Installation Cost

Equipment price is only one line. Structure, mounting, lift access, electrical work, controls, fire coordination, shutdown, commissioning, freight and site constraints shape installed cost.

Open The Field Guide

Project Inquiry

Confirm AirMoveX AXV-H Series For Your Site

Share dimensions, clear height, available power, quantity and destination. The exact series will already be attached to the inquiry.

Start This Product Inquiry