The flagship direct-drive platform for broad, low-speed air movement across high-bay industrial buildings.
Compare This Family ↗
Ceiling Air Movement
AirMoveX AXV-H Series
Premium Six-Blade HVLS Fan
The flagship direct-drive platform for broad, low-speed air movement across high-bay industrial buildings.
AI-generated product illustration, not a product or installation photograph. Confirm the final configuration against the selected-model documents.
- PMSM direct drive
- Six AL6063 airfoil blades
- Motor IP55 (catalog rating)
- VFD safety protection
- Size Range
- 18-24 ft
- Drive
- PMSM direct drive
- Max Air Volume
- 14,900 m³/min
- Installation
- Recommended clear height ≥ 7 m
Product Overview
Configured Around The Building, Not Just The Diameter
The flagship direct-drive platform for broad, low-speed air movement across high-bay industrial buildings.
- Drive
- PMSM direct drive
- Blade
- AL6063 / 6 pcs
- Control
- Variable frequency drive
- Install
- Recommended clear height ≥ 7 m
High-bay warehouses, factories, logistics centers, farms, sports venues and large public halls
Reference values support preliminary selection. Final voltage, size, control, installation accessories, certification scope and packing are confirmed in the quotation.
Why This Model May Fit
AirMoveX AXV-H Series In The AirMoveX System
Use this card as a preliminary fit check. It explains the role of the series from the catalog; the final model, voltage, accessories and installation scope still belong in the quotation.
Typical applications: High-bay warehouses, factories, logistics centers, farms, sports venues and large public halls.
Variable frequency drive. Available variants begin at 7.32 m / 24 ft; review the table below for the series range.
Confirm voltage, selected size, accessories, certification scope, packing, delivery terms and the site installation method against the final configuration.
Carry This Model Into A Quote ↗Available Configurations
AirMoveX AXV-H Series Model Specifications
Select a preliminary configuration below. The inquiry button carries the exact series and model into the project form.
| AirMoveX Model | Diameter | Voltage | Power | Current | Max Speed | Max Air Volume | Coverage / Capacity | Sound | Blades | Net Weight | Inquiry |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AXV-H24-6 | 7.32 m / 24 ft | 220/380 V / 50-60 Hz | 1,500 W | 3.8 A | 50 rpm | 14,900 m³/min | 1,200 m² | ≤ 40 dB(A) | 6 | 121 kg | Quote This Model ↗ |
| AXV-H22-6 | 6.72 m / 22 ft | 220/380 V / 50-60 Hz | 1,400 W | 3.6 A | 55 rpm | 13,500 m³/min | 1,100 m² | ≤ 40 dB(A) | 6 | 117 kg | Quote This Model ↗ |
| AXV-H20-6 | 6.12 m / 20 ft | 220/380 V / 50-60 Hz | 1,200 W | 3.1 A | 60 rpm | 12,200 m³/min | 1,000 m² | ≤ 40 dB(A) | 6 | 105 kg | Quote This Model ↗ |
| AXV-H18-6 | 5.52 m / 18 ft | 220/380 V / 50-60 Hz | 900 W | 2.5 A | 65 rpm | 10,800 m³/min | 900 m² | ≤ 40 dB(A) | 6 | 100 kg | Quote This Model ↗ |
Configuration 01
AXV-H24-6
7.32 m / 24 ft- Diameter
- 7.32 m / 24 ft
- Voltage
- 220/380 V / 50-60 Hz
- Current
- 3.8 A
- Max Speed
- 50 rpm
- Sound
- ≤ 40 dB(A)
- Blades
- 6
- Net Weight
- 121 kg
Configuration 02
AXV-H22-6
6.72 m / 22 ft- Diameter
- 6.72 m / 22 ft
- Voltage
- 220/380 V / 50-60 Hz
- Current
- 3.6 A
- Max Speed
- 55 rpm
- Sound
- ≤ 40 dB(A)
- Blades
- 6
- Net Weight
- 117 kg
Configuration 03
AXV-H20-6
6.12 m / 20 ft- Diameter
- 6.12 m / 20 ft
- Voltage
- 220/380 V / 50-60 Hz
- Current
- 3.1 A
- Max Speed
- 60 rpm
- Sound
- ≤ 40 dB(A)
- Blades
- 6
- Net Weight
- 105 kg
Configuration 04
AXV-H18-6
5.52 m / 18 ft- Diameter
- 5.52 m / 18 ft
- Voltage
- 220/380 V / 50-60 Hz
- Current
- 2.5 A
- Max Speed
- 65 rpm
- Sound
- ≤ 40 dB(A)
- Blades
- 6
- Net Weight
- 100 kg
Before Selecting AirMoveX AXV-H Series
Air circulation, not fresh-air supply. AXV-H moves air within the building. It does not provide an outdoor-air exchange rate or replace source capture for fumes, dust or other process contaminants.
Read the rating at component level. Airflow, coverage and sound figures are supplied catalog references, not measured results for this building. The catalog motor IP55 rating does not establish the same rating for the controller, connectors or complete installation.
Check the mounting and electrical package. Review clear height, the supporting structure, obstacles, mounting details and the exact motor/controller supply before ordering. Confirm site clearances and installation requirements against the selected-model documents.
The values above are supplied catalog references. Use exact-model input at the intended speed and the site's real operating hours to estimate kWh and cost.
Open The Power-Consumption MethodSelection Guides
Resolve These Questions Before Choosing AirMoveX AXV-H Series
Use the guides for the selection method, then confirm the exact configuration against the project documents.
Which parts does an IP rating protect?
Separate the motor rating from controller, cable-entry and installation protection before specifying the environment.
Check 50/60 Hz supply compatibility
Check the input supply, controller and motor as one package; mains frequency alone does not specify fan speed.
Keep VFD fault evidence before resetting
Record the exact alarm and operating conditions, then use the selected drive manual rather than a generic reset sequence.
HVLS Fire Shutdown: Agree the Interface Before Ordering
A fire-shutdown requirement is an interface agreement, not a box to tick next to “remote control”. Settle the signal, stop action and reset ownership before ordering.
HVLS Fans Near Overhead Cranes: Map the Whole Moving Envelope
A crane parked clear of a fan tells you little about tomorrow’s lift. Survey the bridge, trolley, hook and load movement before proposing an HVLS location.
HVLS Fan on a Sloped Ceiling: Survey Before Choosing the Mount
Roof pitch is only one part of a ceiling-fan mounting decision. The supporting member, mount articulation and a vertical fan axis need separate checks.
HVLS vs exhaust: circulation or air exchange?
Separate the circulation layout from exhaust duty and replacement air before comparing quotations.
Freestanding Pole Fan or Ceiling HVLS: Where Does the Load Go?
A floor-supported horizontal-rotor fan avoids a roof attachment but creates a different load path, floor footprint and collision problem.
Industrial Fan Export Packaging: Specify What the Crate Must Protect
For an industrial fan shipment, specify component restraint, separation, moisture protection and the receiving evidence before choosing a crate.
Fan Shipping CBM and Dimensional Weight: Measure the Packed Load
Calculate fan shipment CBM from the outside of every packed piece. Keep volume, actual mass and the carrier’s chargeable-weight rule separate.
HVLS Fans in a Rented Warehouse: Agree the Exit Plan First
For a rented warehouse, compare permission, roof modifications and end-of-lease reinstatement before deciding whether an HVLS installation is worth pursuing.
Fan Blade Tip Speed: Diameter × RPM Is Only the Beginning
Calculate geometric blade-tip speed from rotor diameter and RPM. Keep tip speed separate from delivered airspeed, airflow, noise and safety approval.
Fan Declaration, Certificate or Test Report: Match the Model First
A declaration, certificate and test report answer different questions. Check issuer, product identity, scope and configuration before using any document as purchase evidence.
Single-Phase or Three-Phase Fan: Read the Drive Input First
Compare the site supply, controller input and motor output separately before ordering a single-phase or three-phase industrial fan.
PMSM Fan Motors: Buy the Motor and Controller as a Matched System
A PMSM fan motor needs a controller approved for its exact electrical and mechanical configuration. Match the pair before buying a replacement.
HVLS Fan Modbus Handover: Ask for the Register Map
For an HVLS fan BMS connection, request the actual protocol option, register map, scaling and failure behavior before promising integration.
HVLS Bolt Torque Records: Keep the Joint and Revision Together
An HVLS fan bolt torque record needs the exact joint, fastener and applicable instruction. A generic torque number is not a maintenance record.
Fan VFD Parameter Backups: A File Is Not a Replacement Plan
A fan VFD backup must match the drive, firmware, motor and application. Copying a parameter file is not proof that a replacement is ready to run.
HVLS Maintenance Access: Plan How the Technician Reaches the Fan
Plan HVLS fan maintenance access around the work envelope, floor route, isolation and rotor position before choosing a platform.
Fan Submittal Drawings: Ask for the Installed Envelope
A useful industrial-fan submittal drawing identifies the offered revision, interfaces, service space and open items. A brochure outline is not an installation drawing.
Fan Incoterms and Landed Cost: Name the Place, Then Compare
Compare industrial-fan quotations using the Incoterms rule, named place and itemized buyer costs. An equipment price is not a landed-cost quotation.
Real installations · same factory
Ceiling Fan Systems running on site
Project Documents
Request The Documents That Match The Final Configuration
Document scope is tied to the quoted model and destination market. This avoids presenting a generic certificate or drawing as if it covered every configuration.
Technical Datasheet
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Installation And Dimension Drawing
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Certificate And Packing Scope
Prepared or verified against the selected model, electrical configuration and project scope.
Request This Document ↗Use the HVLS preventive maintenance checklist to organize isolation, mounting and retention, drive, hub, airfoils, controls and return-to-service evidence. Exact intervals and limits still come from the current AirMoveX AXV-H Series documentation.
Open The Maintenance ChecklistWinter destratification is a controlled mixing job: move warmer ceiling air back into the occupied zone slowly enough that people do not feel an unwanted draft.
Open The Field GuideA good specification defines the building, useful-air result, evidence, installation and commissioning. It does not simply ask suppliers for their biggest airflow number.
Open The Field GuideEquipment price is only one line. Structure, mounting, lift access, electrical work, controls, fire coordination, shutdown, commissioning, freight and site constraints shape installed cost.
Open The Field GuideProject Inquiry
Confirm AirMoveX AXV-H Series For Your Site
Share dimensions, clear height, available power, quantity and destination. The exact series will already be attached to the inquiry.