Home/Product Models/HVLS Fans/AirMoveX AXV-L Series
AirMoveX premium five-blade hvls fan shown in a purpose-matched installation scene
Ceiling Fan Systems8-16 ft

Ceiling Air Movement

AirMoveX AXV-L Series

Premium Five-Blade HVLS Fan

A lighter five-blade PMSM platform with tapered airfoils for medium industrial and public interiors.

  • Five tapered airfoils
  • PMSM direct drive
  • 220 V platform
  • Sound reference ≤ 40 dB(A)
Size Range
8-16 ft
Drive
PMSM direct drive
Max Air Volume
8,850 m³/min
Installation
Recommended clear height < 7 m

Product Overview

Configured Around The Building, Not Just The Diameter

A lighter five-blade PMSM platform with tapered airfoils for medium industrial and public interiors.

Drive
PMSM direct drive
Blade
AL6063 / 5 pcs
Control
Variable frequency drive
Install
Recommended clear height < 7 m
Typical Applications

Medium warehouses, workshops, gyms, showrooms, worship spaces and commercial interiors

Reference values support preliminary selection. Final voltage, size, control, installation accessories, certification scope and packing are confirmed in the quotation.

Why This Model May Fit

AirMoveX AXV-L Series In The AirMoveX System

Use this card as a preliminary fit check. It explains the role of the series from the catalog; the final model, voltage, accessories and installation scope still belong in the quotation.

Product familyCeiling Fan Systems

A lighter five-blade PMSM platform with tapered airfoils for medium industrial and public interiors.

Compare This Family ↗
Installation roleRecommended clear height < 7 m

Typical applications: Medium warehouses, workshops, gyms, showrooms, worship spaces and commercial interiors.

Drive and controlPMSM direct drive

Variable frequency drive. Available variants begin at 4.88 m / 16 ft; review the table below for the series range.

Confirm before orderingProject-specific quotation

Confirm voltage, selected size, accessories, certification scope, packing, delivery terms and the site installation method against the final configuration.

Carry This Model Into A Quote ↗

Available Configurations

AirMoveX AXV-L Series Model Specifications

Select a preliminary configuration below. The inquiry button carries the exact series and model into the project form.

AirMoveX ModelDiameterVoltagePowerCurrentMax SpeedMax Air VolumeCoverage / CapacitySoundBladesNet WeightInquiry
AXV-L16-54.88 m / 16 ft220 V / 50-60 Hz800 W4 A70 rpm8,850 m³/min770 m²≤ 40 dB(A)555 kg Quote This Model ↗
AXV-L14-54.28 m / 14 ft220 V / 50-60 Hz800 W4 A90 rpm7,100 m³/min640 m²≤ 40 dB(A)551 kg Quote This Model ↗
AXV-L12-53.68 m / 12 ft220 V / 50-60 Hz700 W3.5 A100 rpm5,700 m³/min470 m²≤ 40 dB(A)540 kg Quote This Model ↗
AXV-L10-53.08 m / 10 ft220 V / 50-60 Hz650 W3.3 A125 rpm5,000 m³/min400 m²≤ 40 dB(A)538 kg Quote This Model ↗
AXV-L08-52.48 m / 8 ft220 V / 50-60 Hz550 W2.8 A155 rpm4,100 m³/min300 m²≤ 40 dB(A)531 kg Quote This Model ↗

Configuration 01

AXV-L16-5

4.88 m / 16 ft
Max Air Volume8,850 m³/min
Power800 W
Coverage770 m²
Diameter
4.88 m / 16 ft
Voltage
220 V / 50-60 Hz
Current
4 A
Max Speed
70 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
55 kg
Request This Configuration

Configuration 02

AXV-L14-5

4.28 m / 14 ft
Max Air Volume7,100 m³/min
Power800 W
Coverage640 m²
Diameter
4.28 m / 14 ft
Voltage
220 V / 50-60 Hz
Current
4 A
Max Speed
90 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
51 kg
Request This Configuration

Configuration 03

AXV-L12-5

3.68 m / 12 ft
Max Air Volume5,700 m³/min
Power700 W
Coverage470 m²
Diameter
3.68 m / 12 ft
Voltage
220 V / 50-60 Hz
Current
3.5 A
Max Speed
100 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
40 kg
Request This Configuration

Configuration 04

AXV-L10-5

3.08 m / 10 ft
Max Air Volume5,000 m³/min
Power650 W
Coverage400 m²
Diameter
3.08 m / 10 ft
Voltage
220 V / 50-60 Hz
Current
3.3 A
Max Speed
125 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
38 kg
Request This Configuration

Configuration 05

AXV-L08-5

2.48 m / 8 ft
Max Air Volume4,100 m³/min
Power550 W
Coverage300 m²
Diameter
2.48 m / 8 ft
Voltage
220 V / 50-60 Hz
Current
2.8 A
Max Speed
155 rpm
Sound
≤ 40 dB(A)
Blades
5
Net Weight
31 kg
Request This Configuration
Power Is Not Annual Energy

The values above are supplied catalog references. Use exact-model input at the intended speed and the site's real operating hours to estimate kWh and cost.

Open The Power-Consumption Method

Selection Guides

Resolve These Questions Before Choosing AirMoveX AXV-L Series

Use the guides for the selection method, then confirm the exact configuration against the project documents.

Real installations · same factory

Ceiling Fan Systems running on site

See all project photos
Metal fabrication workshop — 6-blade HVLS fan
Metal fabrication workshop6-blade HVLS fan
Steel-truss production hall — 6-blade HVLS fan
Steel-truss production hall6-blade HVLS fan
Live concert hall — HVLS fan above the crowd
Live concert hallHVLS fan above the crowd

Project Documents

Request The Documents That Match The Final Configuration

Document scope is tied to the quoted model and destination market. This avoids presenting a generic certificate or drawing as if it covered every configuration.

01

Technical Datasheet

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
02

Installation And Dimension Drawing

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
03

Certificate And Packing Scope

Prepared or verified against the selected model, electrical configuration and project scope.

Request This Document ↗
Planning The Service Record?

Use the HVLS preventive maintenance checklist to organize isolation, mounting and retention, drive, hub, airfoils, controls and return-to-service evidence. Exact intervals and limits still come from the current AirMoveX AXV-L Series documentation.

Open The Maintenance Checklist
HVLS Destratification

Winter destratification is a controlled mixing job: move warmer ceiling air back into the occupied zone slowly enough that people do not feel an unwanted draft.

Open The Field Guide
HVLS Specification Checklist

A good specification defines the building, useful-air result, evidence, installation and commissioning. It does not simply ask suppliers for their biggest airflow number.

Open The Field Guide
HVLS Installation Cost

Equipment price is only one line. Structure, mounting, lift access, electrical work, controls, fire coordination, shutdown, commissioning, freight and site constraints shape installed cost.

Open The Field Guide

Project Inquiry

Confirm AirMoveX AXV-L Series For Your Site

Share dimensions, clear height, available power, quantity and destination. The exact series will already be attached to the inquiry.

Start This Product Inquiry